To view or print the PDF Click HereULTIMA MP68 Minipleat HEPA Filters - 68mm Frame, Grades H10 to U15
Absolute Laminar Flow Filters
TYPICAL APPLICATIONS
To be used for absolute air filtration in controlled contamination environments, installed in terminal filter housings and safety cabinets.
TECHNICAL SPECIFICATION
MEDIA = Glass fibre paper.
SEPARATORS = Cotton threads with hot melt gluing.
FRAME = Anodized aluminium profile 68 mm deep.
FACE GUARDS = Epoxy painted expanded aluminium grids on both sides.
SEALANT = Two components cold moulded polyurethane.
GASKET = One piece cold moulded expanded polyurethane.
EFFICIENCY: H10 to U15
TESTING = Each filter individually tested.
TEMPERATURE = 80°C max.
RELATIVE HUMIDITY = 100% max.
OPTIONS = Antibacterial treatment on request